En catálogo desde el
Deprecated: Array and string offset access syntax with curly braces is deprecated in /home/electric/public_html/framework/i18n/CDateFormatter.php on line 93
25 de abril de 2022
Contadores y tacómetros CntOut SPST+SPDT 12V 2Stage 6Digit Tchmtr
Código: H7CX-AWD1-N
Número de parte: N/A
Categoría:
12 to 24 VDC, 24 VAC, Preset Counter/Tachometer, 2 step, 48 mm x 48 mm, 6 digit, No-voltage/Voltage input selectable=>No-voltage (NPN)/Voltage input (PNP) selectable,Contact output, Memory backup
Código
H7CX-AWD1-N
Fabricante
Omron
Function
1 Stage Preset Counter, 2 Stage Preset Counter, Total Preset Counter, Batch Counter, Dual Counter, Twin counter, Tachometer
Preset stages
2 step
Rated supply voltage
24 VAC 50/60 Hz
12 to 24 VDC (Ripple 20% max.)Operating voltage range
85 to 110% of rated supply voltage (90 to 110% at 12 to 24 VDC)
Power consumption
DC: Approx. 4.7 W (at 12 to 24 VDC)
AC: Approx. 7.2 VA (at 24 VAC)External power supply
12 VDC (±10%) 100 mA(Load reduction is required at DC input)
Count range
-99999 to 999999
Max. counting speed
30 Hz/10 kHz (switching)
Minimum input signal width
30 Hz: 16.7 ms
10 kHz: 0.05 msInput mode
Increment decrement or increment/decrement (UP/DOWN A (command input), UP/DOWN B (individual input) and UP/DOWN C(quadrature input))
Output modes
N, F, C, R, K-1, P, Q, A, K-2, D, L, H
One-shot output time
0.01 to 99.99 s variable
Reset system
External, manual and automatic reset (internal according to C, R, P and Q mode operation)
Input mode
Independent measurements for 1 or 2 inputs, differential input for 2 inputs, absolute ratio for 2 inputs, and error ratio for 2 inputs. (selectable)
Pulse measurement method
Periodic measurement, Pulse width measurement
Max. counting speed
30 Hz
1-input mode: 10 kHz
Except 1-input mode: 5 kHzMinimum input signal width
30 ms(Pulse width measurement (30 Hz))
0.4 ms (1-input mode: 0.2 ms)(Pulse width measurement (5 kHz/10 kHz))Sampling period
Periodic measurement (30 Hz): 200 ms min.
Periodic measurement (5 kHz/10 kHz): 200 ms min./Continuous (minimum interval of 10 ms)
Pulse width measurement: Continuous (minimum interval of 10 ms)Measuring ranges
Periodic measurement (30 Hz): 0.001 to 30.00 Hz
Periodic measurement (5 kHz/10 kHz): 0.01 to 5 kHz (1-input mode: 0.001 Hz to 10 kHz)
Pulse width measurement (30 Hz): 0.030 to 999999 s
Pulse width measurement (5 kHz/10 kHz): 0.0004 to 999999 s (1-input mode: 0.0002 to 999999 s)Output modes
2-input individual measurement: Upper limit/ lower limit
Except 2-input individual measurement: Upper and lower limit/ area/ upper limit/ lower limitInput signal
CP1, CP2, Reset 1, Reset 2
Input method
No-voltage (NPN)/Voltage input (PNP) selectable
No-voltage input (No-contact input)
Short-circuit (ON) impedance: 1 kΩ max. (Leakage current (0 Ω): Approx. 12 mA)
Residual voltage: 3 V max.
Open circuit impedance: 100 kΩ min.No-voltage input (Contact input)
Use a contact which can adequately switch 5 mA at 10 V.
Voltage input
Hight level: 4.5 to 30 VDC
Low level: 0 to 2 VDC (Input resistance Approx. 4.7 kΩ)Contact input
Use a contact which can adequately switch 5 mA at 10 V.
Reset time
External reset
1 ms/20 ms (selectable)
Contact output
Contact form: SPST-NO+SPDT
Switching capacities: 3 A at 250 VAC/30 VDC, resistive load (cos phi=1)
Minimum applicable load: 10 mA at 5 VDC (failure level:P reference value)Display method
7-segment negative transmissive LCD
Digits
6 digit
Character height
Count value: 10 mm (Red, green or orange programmable)
Set value: 6 mm (green)Prescaling function
0.001 to 99.999
Decimal point adjustment
Rightmost 3 digits
Key protection
Key protect Switch
Memory backup methods
Method: EEP-ROM, Number of rewite: 100,000 operations min., Service life: 10 years min.
Ambient temperature (Operating)
-10 to 55 ℃ (with no freezing or condensation)
Close mounting: -10 to 50 ℃ (with no freezing or condensation)Ambient temperature (Storage)
-25 to 70 ℃ (with no freezing or condensation)
Ambient humidity (Operating)
25 to 85% RH
Insulation resistance
Between current carrying terminals and exposed non-current carrying metal parts: 100 MΩ min. (at 500 VDC)
Between non-continuous contacts: 100 MΩ min. (at 500 VDC)Dielectric withstand voltage
Between current carrying metal parts and non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min
Between operating power circuit and input circuit: 1000 VAC 50/60 Hz 1 min
Between control output, and power supply/input circuit: 2000 VAC 50/60 Hz 1 min
Between non-continuous contacts: 1000 VAC 50/60 Hz 1 minImpulse withstand voltage
Between power terminals: 1 kV
Between current carrying terminals and exposed non-current carrying metal parts: 1.5 kVNoise immunity
Between power terminals: ±1.5 kV
Between input terminals: ±600 V
square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)Static immunity
Mulfunction: 8 kV, Destruction: 15 kV
Vibration resistance
Destruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h
Malfunction: 10 to 55 Hz 0.35 mm single amplitude each in 3 directions for 10 minShock resistance
Destruction: 300 m/s2, 3 times each in 3 axes each directions
Malfunction: 100 m/s2, 3 times each in 3 axes each directionsLife expectancy
Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load, 23 ℃)
Mechanical: 10 million operations min.Degree of protection
Case front: IEC IP66, UL508 Type 4X (indoors) (when using the Y92S-29 Waterproof Packing)
External connection method
Screw terminal
Case color
Black (Munsell N1.5)
Accessories
Flush mounting adapter, Waterproof packing, Terminal Cover, Label for DIP switch settings
Weight
Approx. 130 g
Ancho: N/A
Alto: N/A
Profundo: N/A
Peso: N/A
Términos de entrega: N/A