• H7CX-AWD1-N clavija dos polos en Toluca

    H7CX-AWD1-N

coloque el cursor sobre la imagen para ampliar


Solicitar precio

Costo de envío NO incluido en el precio

Existencia: 1

En catálogo desde el
Deprecated: Array and string offset access syntax with curly braces is deprecated in /home/electric/public_html/framework/i18n/CDateFormatter.php on line 93
25 de abril de 2022

Contadores y tacómetros CntOut SPST+SPDT 12V 2Stage 6Digit Tchmtr

Código: H7CX-AWD1-N

Número de parte: N/A

Categoría:

12 to 24 VDC, 24 VAC, Preset Counter/Tachometer, 2 step, 48 mm x 48 mm, 6 digit, No-voltage/Voltage input selectable=>No-voltage (NPN)/Voltage input (PNP) selectable,Contact output, Memory backup

Código

H7CX-AWD1-N

Fabricante

Omron

Function

1 Stage Preset Counter, 2 Stage Preset Counter, Total Preset Counter, Batch Counter, Dual Counter, Twin counter, Tachometer

Preset stages

2 step

Rated supply voltage

24 VAC 50/60 Hz
12 to 24 VDC (Ripple 20% max.)

Operating voltage range

85 to 110% of rated supply voltage (90 to 110% at 12 to 24 VDC)

Power consumption

DC: Approx. 4.7 W (at 12 to 24 VDC)
AC: Approx. 7.2 VA (at 24 VAC)

External power supply

12 VDC (±10%) 100 mA(Load reduction is required at DC input)

Count range

-99999 to 999999

Max. counting speed

30 Hz/10 kHz (switching)

Minimum input signal width

30 Hz: 16.7 ms
10 kHz: 0.05 ms

Input mode

Increment decrement or increment/decrement (UP/DOWN A (command input), UP/DOWN B (individual input) and UP/DOWN C(quadrature input))

Output modes

N, F, C, R, K-1, P, Q, A, K-2, D, L, H

One-shot output time

0.01 to 99.99 s variable

Reset system

External, manual and automatic reset (internal according to C, R, P and Q mode operation)

Input mode

Independent measurements for 1 or 2 inputs, differential input for 2 inputs, absolute ratio for 2 inputs, and error ratio for 2 inputs. (selectable)

Pulse measurement method

Periodic measurement, Pulse width measurement

Max. counting speed

30 Hz
1-input mode: 10 kHz
Except 1-input mode: 5 kHz

Minimum input signal width

30 ms(Pulse width measurement (30 Hz))
0.4 ms (1-input mode: 0.2 ms)(Pulse width measurement (5 kHz/10 kHz))

Sampling period

Periodic measurement (30 Hz): 200 ms min.
Periodic measurement (5 kHz/10 kHz): 200 ms min./Continuous (minimum interval of 10 ms)
Pulse width measurement: Continuous (minimum interval of 10 ms)

Measuring ranges

Periodic measurement (30 Hz): 0.001 to 30.00 Hz
Periodic measurement (5 kHz/10 kHz): 0.01 to 5 kHz (1-input mode: 0.001 Hz to 10 kHz)
Pulse width measurement (30 Hz): 0.030 to 999999 s
Pulse width measurement (5 kHz/10 kHz): 0.0004 to 999999 s (1-input mode: 0.0002 to 999999 s)

Output modes

2-input individual measurement: Upper limit/ lower limit
Except 2-input individual measurement: Upper and lower limit/ area/ upper limit/ lower limit

Input signal

CP1, CP2, Reset 1, Reset 2

Input method

No-voltage (NPN)/Voltage input (PNP) selectable

No-voltage input (No-contact input

Short-circuit (ON) impedance: 1 kΩ max. (Leakage current (0 Ω): Approx. 12 mA)
Residual voltage: 3 V max.
Open circuit impedance: 100 kΩ min.

No-voltage input (Contact input

Use a contact which can adequately switch 5 mA at 10 V.

Voltage input

Hight level: 4.5 to 30 VDC
Low level: 0 to 2 VDC (Input resistance Approx. 4.7 kΩ)

Contact input

Use a contact which can adequately switch 5 mA at 10 V.

Reset time

External reset

1 ms/20 ms (selectable)

Contact output

Contact form: SPST-NO+SPDT
Switching capacities: 3 A at 250 VAC/30 VDC, resistive load (cos phi=1)
Minimum applicable load: 10 mA at 5 VDC (failure level:P reference value)

Display method

7-segment negative transmissive LCD

Digits

6 digit

Character height

Count value: 10 mm (Red, green or orange programmable)
Set value: 6 mm (green)

Prescaling function

0.001 to 99.999

Decimal point adjustment

Rightmost 3 digits

Key protection

Key protect Switch

Memory backup methods

Method: EEP-ROM, Number of rewite: 100,000 operations min., Service life: 10 years min.

Ambient temperature (Operating)

-10 to 55 ℃ (with no freezing or condensation)
Close mounting: -10 to 50 ℃ (with no freezing or condensation)

Ambient temperature (Storage)

-25 to 70 ℃ (with no freezing or condensation)

Ambient humidity (Operating)

25 to 85% RH

Insulation resistance

Between current carrying terminals and exposed non-current carrying metal parts: 100 MΩ min. (at 500 VDC)
Between non-continuous contacts: 100 MΩ min. (at 500 VDC)

Dielectric withstand voltage

Between current carrying metal parts and non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min
Between operating power circuit and input circuit: 1000 VAC 50/60 Hz 1 min
Between control output, and power supply/input circuit: 2000 VAC 50/60 Hz 1 min
Between non-continuous contacts: 1000 VAC 50/60 Hz 1 min

Impulse withstand voltage

Between power terminals: 1 kV
Between current carrying terminals and exposed non-current carrying metal parts: 1.5 kV

Noise immunity

Between power terminals: ±1.5 kV
Between input terminals: ±600 V
square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)

Static immunity

Mulfunction: 8 kV, Destruction: 15 kV

Vibration resistance

Destruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h
Malfunction: 10 to 55 Hz 0.35 mm single amplitude each in 3 directions for 10 min

Shock resistance

Destruction: 300 m/s2, 3 times each in 3 axes each directions
Malfunction: 100 m/s2, 3 times each in 3 axes each directions

Life expectancy

Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load, 23 ℃)
Mechanical: 10 million operations min.

Degree of protection

Case front: IEC IP66, UL508 Type 4X (indoors) (when using the Y92S-29 Waterproof Packing)

External connection method

Screw terminal

Case color

Black (Munsell N1.5)

Accessories

Flush mounting adapter, Waterproof packing, Terminal Cover, Label for DIP switch settings

Weight

Approx. 130 g


Ancho: N/A

Alto: N/A

Profundo: N/A

Peso: N/A

Términos de entrega: N/A


Productos relacionados

WT160-F420

WT160-F420

Fotocélula
SICK
J60030-3P

J60030-3P

PORTAFUSIBLE

CLASE J, 3 POLOS, 30 A, TIPO FUSE BLOCKS

600 V, MONTAJE DE TORNILLO.<
NJ20-U1-W

NJ20-U1-W

SENSOR INDUCTIVO
NJ20+U1+W
MT226024

MT226024

RELÉ ENCHUFABLE,

8 PINES, 24 V AC 50/60 Hz

LUCA1XBL

LUCA1XBL

UNIDAD DE CONTROL ESTÁNDAR LUCA
CLASE 10 - 0,35...1,4 A - 24 V CD

SIM-M8-3GD-2,5-PU

SIM-M8-3GD-2,5-PU

CABLE DE CONEXIÓN



Comentarios